ArmaFlex ECO550 Activator for ArmaFlex ECO550 & Ultima ECO550 Adhesive
How to measure?
Pipe insulation sizes refer to the outside diameter of the pipe — not the bore (internal diameter).
|←— OD —→|Wrap a tape measure around the pipe, divide by π (3.14) to get the OD. Or use calipers across the outside of the pipe directly.
ArmaFlex ECO550 Activator
The ECO550 Activator is used alongside ArmaFlex ECO550 and ArmaFlex Ultima ECO550 adhesives to dramatically reduce airing time on site. Without the activator, ECO550 adhesive requires approximately 10 minutes of airing before bonding. With the activator applied to both surfaces, airing time drops to just 1–2 minutes — enabling immediate bonding and significantly faster installation, particularly on larger commercial jobs where joint count is high.
Supplied as a 100 ml plastic bottle. Armacell carton quantity: 6 bottles.
The activator does not replace the adhesive — it is sprayed onto both bonding surfaces prior to adhesive application. It contains no halogens, fulfils VOC requirements across all major European standards, and carries UL ECOLOGO® certification (UL 2762), making it suitable for LEED, BREEAM, and DGNB projects alongside NH/ArmaFlex Smart or standard ArmaFlex EVO systems.
When to Use the Activator
- Any job where installation speed matters and you are using ECO550 or Ultima ECO550 adhesive
- Commercial projects with high joint counts where 10-minute airing per joint is impractical
- Cold conditions where airing time naturally extends — activator compensates by accelerating cure
- LEED, BREEAM, or DGNB projects requiring low-VOC, halogen-free adhesive systems
Key Benefits
- Reduces airing time from ~10 minutes to just 1–2 minutes
- Enables immediate bonding after application
- Halogen-free, low-VOC formulation
- UL ECOLOGO® certified (UL 2762)
- Complies with French, Italian, Belgian, German AgBB VOC requirements
Technical Properties
| Property | Value | Standard |
|---|---|---|
| Content | 100 ml | — |
| Carton Quantity | 6 bottles | — |
| Service Temperature | −50°C to +100°C | — |
| Weather Resistance | Very good | — |
| VOC Content | Fulfils all major European VOC requirements | — |
| Flash Point | Not applicable | — |
| Shelf Life | 12 months from date of manufacture | — |
Application Conditions
- Apply from a minimum distance of 30 cm to both bonding surfaces
- Ideal temperature: +15°C to +20°C; do not apply below +5°C
- Maximum relative humidity: 70%
- Minimum airing time after activator application: 1–2 minutes (in combination with ECO550 or Ultima ECO550 adhesive)
- Setting time: 36 hours
Yield
- ArmaFlex tubes (all thicknesses 10–40mm): >0.5 g/m per butt joint; >2 g/m for butt + longitudinal joint combined
- ArmaFlex sheets: 8–10 g/m²
Storage
- Store in sealed original container, cool and dry (+15°C to +35°C; not below +5°C)
- Shelf life: 12 months from manufacture
Disposal
Allocate a waste code in accordance with the European Waste Catalogue. Remove residuals from packaging before disposal. Refer to the Safety Data Sheet for full guidance — MSDS available on request.