Kingspan Kooltherm Phenolic Pipe Insulation 1m Long - Pipelagging.com

Kingspan Kooltherm Phenolic Pipe Insulation 1m Long

15mm / 15mm
£6.89 inc VAT £5.74 ex VAT
Skip to product information
Kingspan Kooltherm Phenolic Pipe Insulation 1m Long - Pipelagging.com
1/5

Kingspan Kooltherm Phenolic Pipe Insulation 1m Long

K15X15
£6.89 inc VAT £5.74 ex VAT
Insulation Thickness (mm)
Pipe Size (mm)
Free UK delivery on orders over £100
Usually dispatched within 1–2 working days
Secure checkout · 30-day returns
How to measure?
Measure the Outside Diameter (OD)
Pipe insulation sizes refer to the outside diameter of the pipe — not the bore (internal diameter).

|←— OD —→|
Wrap a tape measure around the pipe, divide by π (3.14) to get the OD. Or use calipers across the outside of the pipe directly.

Kingspan Kooltherm Phenolic Pipe Insulation – 1m Long

Kingspan Kooltherm Pipe Insulation is a rigid, fibre-free phenolic insulation system for building-services and industrial pipework. It combines low thermal conductivity with a compact insulation thickness, making it well suited to space-constrained plant rooms, risers and service zones.

Supplied in pre-formed 1 metre pipe sections with an outer foil facing. Select the required pipe outside diameter and insulation thickness from the available variants.

Key Features

  • Low thermal conductivity: as low as 0.025 W/(m·K) at +10°C, depending on product configuration
  • Operating temperature: -50°C to +110°C for Kooltherm pipe sections
  • Closed-cell content: greater than 90%
  • Reaction to fire: HVAC-foil-faced pipe sections up to 300mm diameter achieve Euroclass BL-s1,d0 in the tested configuration
  • Space efficient: high thermal performance can allow thinner insulation thicknesses than many conventional alternatives for the same design duty
  • Factory-applied facing: reinforced foil outer face provides a neat finish and vapour-control layer when joints are correctly sealed

Applications

  • Heating and hot-water pipework
  • Chilled-water services
  • HVAC and building-services pipework
  • Commercial plant rooms and risers
  • Industrial pipework within the stated service-temperature range

Technical Notes

For services operating below 0°C, Kingspan recommends use of a factory-applied low-permeability vapour-barrier jacket suitable for the application. Insulation thickness should be selected to meet the project design, operating temperature and applicable specification requirements.

Where compliance with BS 5422:2023, Building Regulations or a project-specific heat-loss requirement is needed, use the required calculated thickness rather than selecting insulation thickness by pipe diameter alone.

Installation

Fit the pre-formed sections closely around the pipe and seal longitudinal and circumferential joints in accordance with Kingspan installation guidance. Maintain continuity of the foil facing and vapour-control layer, particularly on chilled-water and below-ambient systems.

Complete Your Installation

Use a suitable aluminium foil tape compatible with the facing to seal joints and maintain a continuous finish. For specification support or wall-thickness selection, refer to current Kingspan Technical Insulation guidance or contact our team.